Products - KIMMCO Duct Liner (KDL)
 

Applications

For internal insulation of ducts and air handling equipment where sound absorption is required. Sound absorption treatment of walls and ceilings, acoustic enclosures etc...

Description

Produced from strong resilient glass fibres, free from shot and coarse fibres. Easy to handle cut and fit.

KIMMCO Duct Liner is available in flexible roll form and semi rigid slabs.

KIMMCO Duct Liner has a strong punchure resisting facing which is carefully bonded to the glass fibre mat during manufacture.

Facings

Faced with a non-woven, strong, dimensionally stable black glass tissue to provide a highly efficient sound absorption performance free from fibre emission at internal air velocities up to 25 metres per second (4920 ft/minute).
 

Standard Dimensions Nominal Density
Thickness Width Length
Roll Board
15 mm
25 mm
50 mm
1.2m 20m 1m
Other Dimensions available 
KDL Kg/m3 Lbs/ft3
16
24
32
48
60
16
24
32
48
60
1.0
1.5
2.0
3.0
3.75
Other Densities available
Performances

Working Temperature

    Fibre        :   230 ºC
    Facing      :   230 ºC
 

Permeance

Dimensionally stable under varying conditions of temperature and humidity, rot proof, odourless, non-hygroscopic and will not sustain vermin or fungus.They will not shrink due to the age or temperature variations. They will maintain their performances throughout the life time of the construction.

Thermal Conductivity

Thermal Conductivity in W/m.K
Mean Temperature
ºC
For the densities in kg/m3
16 24 32 48 60
0 0.034 0.031 0.030 0.029 0.030
10 0.036 0.032 0.031 0.030 0.031
25 0.039 0.035 0.033 0.031 0.032
50 0.044 0.039 0.037 0.035 0.036
75 0.051 0.043 0.040 0.037 0.038
100 0.057 0.047 0.044 0.041 0.042
Thermal Conductivity in Btu.in/ft2 h.F
Mean Temperature
ºF
For the densities in Lbs/ft3
1 1.500 2 3 3.750
32 0.23 0.21 0.20 0.20 0.21
50 0.25 0.22 0.22 0.21 0.21
77 0.27 0.24 0.23 0.22 0.23
122 0.31 0.27 0.25 0.24 0.24
167 0.35 0.30 0.27 0.26 0.26
212 0.40 0.33 0.30 0.29 0.29

Fire Safety

Base fibre Non combustible when tested in accordance with ASTM E 84,
BS 476 (Part 4)

KIMMCO Duct Liner has been tested and listed by UNDERWRITERS LABORATORIES according to UL 723 (File R9073).

Moisture Absorption

Less than 1% by volume when tested in accordance with BS 2972 and 6676, ASTM C 665.

KIMMCO Duct Liner does not absorb moisture from the ambient air nor water by capillary attraction. Only water under pressure can enter the insulation products, but that will quickly dry out owing to the material's open cell structure.

Non Toxic

KIMMCO DUCT LINER IS NOT HAZARDOUS TO HEALTH (see KIMMCO MSDS).

Acoustics

KIMMCO Duct Liner is especially designed to provide exceptional sound absorption to acoustically sensitive environments and/or equipments as air-conditioning equipments, auditoriums, theatres, studios, acoustical building assemblies, curtain walls.

Product Absorption coefficient at the octave band frequencies (Hz)  
Type Thickness
mm
125 250 500 1000 2000 4000 NRC
KDL 16 25 0.06 0.20 0.29 0.40 0.50 0.54 0.50
50 0.24 0.51 0.72 0.90 0.94 0.98 0.80
KDL 24 25 0.12 0.31 0.64 0.83. 0.95 0.99 0.70
50 0.27 0.69 1.01 1.07 1.06 1.05 0.95
KDL 32 15 0.05 0.13 0.32 0.65 0.79 0.93 0.45
25 0.14 0.36 0.65 0.86 0.98 1.00 0.70
50 0.24 0.77 1.02 1.04 1.04 1.01 0.95
KDL 48 15 0.05 0.12 0.29 0.51 0.68 0.80 0.40
25 0.12 0.32 0.73 0.98 1.02 1.00 0.75
50 0.30 0.85 1.03 1.07 1.06 1.00 1.00
KDL 60 25 0.06 0.19 0.62 0.83 0.90 0.95 0.65
50 0.21 0.75 1.00 1.00 1.00 0.95 0.95

Test in accordance with ASTM C 423 using Type A mounting as per ASTM E 795.These are typical values subject to normal manufacturing and testing variances.

Internal Erosions

The internal erosion is nil with air velocity up to 25m/s or 4920 feet per minute, when tested according to SMACNA procedure.


Linear Losses

The following diagram is established for air at 20 ºC (68 ºF) and 760 mm Hg.

Click to Enlarge

 

Conformity to Standards

Kimmco Duct Liner complies with the following Standards.

American Standards

ASTM C 167,168,177,411,423, 518,665 §13.8 & 13.9,1071,1101/1101M, 1104/1104M,1335;E 84,477,795 UL 181,723 F.S. HH-I-545B NFPA 255, NFPA 90A & 90B NAIMA Standards SMACNA Standards

British Standards

BS 476 (parts 4,6&7), 874,2972,3533,5643,5720

German Standards

DIN 18165, 52612

ISO

354,8301,8302,9229,9291

Typical Installation
 

KIMMCO Duct Liner has been developed to exacting specifications and uses materials of the highest quality. To obtain maximum performance the following installation procedures should be followed:

Measure and cut to shape the Duct Liner allowing a 5cm excess at down stream transverse joints. Carefully remove insulation from 5cm excess leaving only the surface tissue for overlapping to next section. Longitudinal joints should be close butted and sealed with a proprietary sealant, tape or metal angle. Ensure that internal surface of duct is clean and free from dust and grease.

 

Affix mechanical fasteners in accordance with manufacturers instructions at not more than 45cm centres. 

Fixings should start within 7.5cm of joints corners, ends etc. 

Apply suitable adhesive to duct surface before positioning Duct Liner over mechanical fastener pins. Fit washers or caps to pins and snip off excess shank of pins.

Transverse joints should have 5cm tissue flap fixed to following section of liner with adhesive then overlay with metal strip fixed through insulation to dust sheeting by screws or rivets at 7.5cm centres. Start and finish ends of duct section to be treated as above with exposed edges of insulation coated with sealant or alternatively affix angle in place of metal strip with one leg masking edge or insulation.

 
logo_kimmco2.gif
Alghanim Industries Industrial Group invited to provide its expertise at recently held "Future Airport" Conference, Dubai
KIMMCO promoting Glass wool and Stone wool insulation at Project Qatar
KIMMCO promotes safety with the KAIZEN week
KIMMCO educates the market
KIMMCO INSULATION grows with the Big 5 Show 2008
KIMMCO efforts rewarded by Kuwaiti Ministry of Public Works
KIMMCO seeks synergies at the Kuwait Contractors Exhibition and Conference
KIMMCO - ISOVER Conference on Insulation, Dubai
  
  
Best viewed on Internet Explorer 6.0 and Netscape 6.1 and above.
Copyright © 2003 - 2009 Alghanim Industries and Yusuf A. Alghanim & Sons w.l.l. | Terms & Conditions